This issue occurs if the SCSI controller is not added to proper SCSI port. For example, if the first SCSI controller is added at SCSI Port-1 then the second SCSI controller must be added at SCSI Port-2 and third SCSI controller must be added at SCSI Port-3 and so on.
VDDK expects the SCSI Port acquired for each of the SCSI controller to be in order when the initial disks are added to each of those controllers. If the first SCSI controller is added at SCSI Port-2 then during HotAdd mechanism VDDK expects the second SCSI controller to be added in SCSI Port-3 and third SCSI controller to be added in SCSI Port-4 and so on. If the SCSI controllers are not added in the above mentioned order then HotAdd mechanism fails.
To verify that the SCSI controller are added to the proper SCSI port:
-
Click Start > Run., type regedit and click OK.
-
Navigate to Computer\HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\Scsi.