Issue/Introduction
This article provides information on creating an alarm for Storage Path Redundancy, and to alert users when storage connectivity is lost.
Environment
VMware vCenter Server 6.5.x
VMware vCenter Server 8.0
VMware vCenter Server 7.0.x
VMware vCenter Server 6.7.x
Resolution
To create an alarm that triggers when the Storage Path Redundancy or storage connectivity is lost:
Click your cluster in vCenter Server.
Click the
Alarms
tab.
Click
Definitions
(next to View).
Right-click the blank space and click
New Alarm
.
Set Alarm Type Monitor to
Hosts
.
Select the
Monitor for specific events occurring on this object, for example VM powered On
option.
Click the
Triggers
tab.
Click
Add
.
Click the first
Event
field that is added.
From the dropdown menu, select
Lost Storage Path Redundancy
.
Repeat these steps and add
Lost Storage Connectivity
.
To get email notifications when the alarm triggers:
Click the
Actions
tab.
Click
Add
.
Under configuration, enter your destination email.
Click
OK
.
Click
Administration
>
vCenter Server Settings
>
Mail
.
Enter your SMTP information.