さらに次の症状が発生します。
- C:\ProgramData\VMware\vCenterServer\logs\vsphere-client\logs\vsphere_client_virgo.log ファイルに、次のようなエントリが表示される。
[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2644 70000359 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2681 70000363 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2718 70000367 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2755 70000371 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2792 70000375 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2830 70000378 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2867 70000382 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time>[YYYY-MM-DDT<time>] [ERROR] data-service-pool-2904 70000387 100006 200003 com.vmware.vsphere.client.cimmonitor.impl.CimMonitorFacade Missing hardware health data for host ManagedObjectReference: type = HostSystem, value = host-1234, serverGuid = 616fd8e7-d733-1234-a73a-bd09dbd1afe2
</time> - /var/log/syslog.log ファイルに次のようなエントリが表示される。
2015-11-27T08:30:55Z sfcb-CIMXML-Processor[290157]:pam_succeed_if(sfcb:auth): error retrieving information about user 52457c59-638d-9db9-7c4e-789b84896558
- コマンド プロンプトで C:\Program Files\VMware\vCenter Server\vmware-vws\wbin\diag.bat | more コマンドを実行すると、次のようなエントリが返される。
<errors>
<group name="Memory">
<CIM_PhysicalMemory><resourceKey>cis.vws.operation.failure.CIM_ERR_INVALID_NAMESPACE</resourceKey>
<host>hostname.domain.com</host>
<errCode>3</errCode>
<errMsg>Invalid namespace</errMsg>
<localErrMsg>Invalid namespace</localErrMsg>
</CIM_PhysicalMemory>
</group>
<group name="BMC">
<SMX_ManagementProcessor><resourceKey>cis.vws.operation.failure.CIM_ERR_INVALID_NAMESPACE</resourceKey>
<host>hostname.domain.com</host>
<errCode>3</errCode>
<errMsg>Invalid namespace</errMsg>
<localErrMsg>Invalid namespace</localErrMsg>
</SMX_ManagementProcessor>
</group>
</errors>
注:前述のログの引用は単なる例です。日付、時間、および環境変数は、環境によって異なる場合があります。
この記事の更新時にアラートを受信する場合は、[Actions] ボックスで Subscribe to Article をクリックしてください