ESXi/ESX ホストで次のアラートが報告される:DRS 設定をホストに適用できません。親リソース プールで使用可能な CPU リソースが、この操作に対して不足しています (Unable to apply DNS settings on host. The available CPU resources in the parent resource pool are insufficient for the operation)
book
Article ID: 339037
calendar_today
Updated On:
Products
VMware vCenter ServerVMware vSphere ESXi
Issue/Introduction
ESX/ESXi ホストの [サマリ] タブに、次のアラートが報告される。
Unable to apply DRS settings on host. The available CPU resources in the parent resource pool are insufficient for the operation.
/var/log/hostd.log ファイルに、次のようなエントリが記録される。
2013-02-05T03:39:02.327Z [58597B90 info 'TaskManager' opID=HB-host-47@98-33a6b6f7-4f] Task Created : haTask-ha-root-pool-vim.ResourcePool.updateChildResourceConfiguration-321049836 2013-02-05T03:39:02.328Z [58597B90 info 'vm:/vmfs/volumes/50b3185d-da6a6a33-6bc5-00215e4cb5da/example-domain.com/example-domain.com.vmx' opID=HB-host-47@98-33a6b6f7-4f] State Transition (VM_STATE_ON -> VM_STATE_RECONFIGURING) 2013-02-05T03:39:02.328Z [58597B90 warning 'HostsvcPlugin' opID=HB-host-47@98-33a6b6f7-4f] CPU/Memory resource update failed: Sysinfo error on operation returned status : Admission check failed for cpu resource. Please see the VMkernel log for detailed error information 2013-02-05T03:39:02.328Z [58597B90 info 'vm:/vmfs/volumes/50b3185d-da6a6a33-6bc5-00215e4cb5da/example-domain.com/example-domain.com.vmx' opID=HB-host-47@98-33a6b6f7-4f] RsrcMgr failed to update resource config: vim.fault.InsufficientCpuResourcesFault 2013-02-05T03:39:02.330Z [58340B90 info 'Hbrsvc'] Replicator: powerstate change VM: 3 Old: 1 New: 1 2013-02-05T03:39:02.330Z [58340B90 verbose 'Hbrsvc'] Replicator: Remove group no matching entry for VM (id=3) 2013-02-05T03:39:02.330Z [58340B90 verbose 'vim.PerformanceManager'] Adding vm 3 to poweredOnVms list 2013-02-05T03:39:02.330Z [58597B90 info 'Vmomi' opID=HB-host-47@98-33a6b6f7-4f] Throw vim.fault.InsufficientCpuResourcesFault 2013-02-05T03:39:02.332Z [58597B90 info 'Vmomi' opID=HB-host-47@98-33a6b6f7-4f] Result: --> (vim.fault.InsufficientCpuResourcesFault) { --> dynamicType = <unset>, --> faultCause = (vmodl.MethodFault) null, --> faultMessage = (vmodl.LocalizableMessage) [ --> (vmodl.LocalizableMessage) { --> dynamicType = <unset>, --> key = "vob.sched.group.cpu.admitfailed", --> arg = (vmodl.KeyAnyValue) [ --> (vmodl.KeyAnyValue) { --> dynamicType = <unset>, --> key = "1", --> value = "vm.4972", --> }, --> (vmodl.KeyAnyValue) { --> dynamicType = <unset>, --> key = "2", --> value = "4096", --> }, --> (vmodl.KeyAnyValue) { --> dynamicType = <unset>, --> key = "3", --> value = "mhz", --> } --> ], --> message = "Group vm.4972: Can't admit VM: CPU admission check failed. Invalid reservation 4096 mhz --> ", --> } --> ], --> unreserved = -1, --> requested = -1, --> msg = ""