VMware Cloud Foundation 2.2 Bringup process fails to proceed beyond Rack Discovery step
book
Article ID: 336771
calendar_today
Updated On:
Products
VMware Cloud Foundation
Issue/Introduction
Symptoms:
- VMware Cloud Foundation 2.2 Bringup process fails to proceed beyond Rack Discovery step
- The ESXi servers in the rack are manufactured by Hitachi
- Investigating the Top-of-Rack (ToR) switch configuration reveals that VLAN 4 is not configured
Environment
VMware Cloud Foundation 2.2.x
Resolution
This is a known issue affecting VMware Cloud Foundation 2.2. Currently there is no resolution.
Workaround:
To workaround this issue, manually configure VLAN 4 on the ToR switches. Refer to switch vendor documentation for specific steps.