Multicast traffic is dropped when Arista Switches are utilized in VMware NSX for vSphere 6.2
book
Article ID: 336605
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
Symptoms:
When you have Arista switches with your VMware NSX for vSphere 6.2.x environment, you experience these symptoms:
- All Broadcast, Unknown unicast, and Multicast (BUM) traffic is not working
- All multicast packets that arrives at the VXLAN Tunnel End Point (VTEP) are dropped
- The host drops any received multicast packets if the VXLAN UDP port is set to the default 8472 value
Environment
VMware NSX for vSphere 6.2.x
Cause
This issue occurs on all Arista 7150 products that are running version EOS 4.12
Note: Arista EOS-4.12.7.1 drops multicast packets through port 8472. EOS-4.14.2F forwards the traffic properly.
Resolution
This is not a VMware issue.
To resolve this issue:
- Upgrade EOS to version 4.13.0 or later. For more information, see Arista Support.
- Configure NSX to use a different UDP port using REST API, specifically to 4789 per the VXLAN specification.
Feedback
thumb_up
Yes
thumb_down
No