VPX_TEXT_ARRAY table growth causes the vCenter Server database to run out of space
book
Article ID: 336272
calendar_today
Updated On:
Products
VMware vCenter Server
Issue/Introduction
Symptoms:
VPX_TEXT_ARRAY table increases over time
The VMware VirtualCenter Server service fails
This issue occurs when the vCenter Server database is full
Purging old data from the database used by the vCenter Server does not resolve the issue
Shrinking the data from the database does not resolve the issue
Shrinking the transaction logs does not help in reducing the database size
Environment
VMware vCenter Server 6.5.x
Cause
The VPX_TEXT_ARRAY table growth is due to latent snapshot data. This is due to a failed hostsync which will fail to update VC and as a result latent data will be left in the VPX_TEXT_ARRAY table eventually culminating in the table growth.
Resolution
This issue is resolved in vSphere 6.5 U3 available at VMware Download.