Ideal IDBATCH job 1-IDADIDIN22D - Neither Datacom/DB not DB2 support is installed.
search cancel

Ideal IDBATCH job 1-IDADIDIN22D - Neither Datacom/DB not DB2 support is installed.

book

Article ID: 33531

calendar_today

Updated On:

Products

Ideal

Issue/Introduction

Any attempt to run IDBATCH batch job fails with errors: 

+ICSCBTIN01I - DATADICTIONARY WAS OPENED SUCCESSFULLY 
+IDADIDIN93D - INTERR: IDEAL INSTALLATION ERROR. 
+IDADIDIN95D - NO DATABASE FOUND 
 
1-IDADIDIN22D - Neither Datacom/DB nor DB2 support is installed 

Cause

The Ideal load module @IADFLGS is not legitimate. Either the @IADFLGS module was not prepared by assembling macro ADFLGS or that macro ADFLGS was assembled without specifying either Datacom or DB2 as "Y" (yes) to identify the database in use:

ADFLGS   CSECT                                 
         ADFLAGS TYPE=DC,DB=y/n,DB2=y/n,VSAM=y/n     
         END                               

Resolution

Reassemble ADFLGS with "DB=Y" for Datacom usage or "DB2=Y" for Ideal for DB2 product usage.