LINT1/NMI (motherboard nonmaskable interrupt), undiagnosed. This may be a hardware problem; please contact your hardware vendor.WARNING: IOMMUIntel: 2211: IOMMU Unit # 0: R/W = 1, Device 007:00.0 Faulting PA = 0xdf63e000 Fault Reason = 6/var/log/vmkernel.log file, on the console, or in the VMkernel core dump file if the condition triggers a VMkernel purple diagnostic screen.To troubleshoot and resolve an NMI event, perform the following steps:
Isolate Virtual Machine triggers: Identify which Virtual Machines (if any) were powered on at the time of the NMI event. Check if powering on a specific Virtual Machine consistently triggers the crash.
Inspect physical hardware: Reseat the physical PCI cards in the host, or attempt moving them to different PCIe slots to rule out a seating or slot issue.
Contact your hardware vendor: Because an NMI is typically a hardware-level interrupt, you may need to engage your hardware vendor for further diagnosis. When opening a support case, ensure you provide the following diagnostic data:
The exact timeframe the event occurred.
At least 10 minutes of logs leading up to the event.
Chassis diagnostics log output and management chipset log output.
Chassis vital product data (VPD).
A complete vm-support log bundle from the affected ESXi/ESX host.
Notes: