Symptoms:
In an Enhanced or Standard HA deployment the active SASE SD-WAN Edge might:
  • Show unknown value in the "peer serial number" section.
  • Fail to detect links on the standby Edge.
  • Fail to route traffic through the Standby Edge WAN links.


Environment

VMware SD-WAN
VMware SD-WAN by VeloCloud

Cause

This issue is caused by defect id: 110564.
The problem is seen when a child process takes over the TCP port used for Active-Standby communication, leading to TCP session to fail and HA information not being exchanged as expected.

Resolution

The fix is included in SASE SD-WAN Edge software releases:
5.2.0.0 (R5200-20230530-GA) or later
4.5.2 (R452-20230628-GA) or later

For information on how to upgrade please check VMware SD-WAN Software Upgrade FAQs

Workaround:
Restarting the Active Edge in the HA pair will allow it to come back up normally.