GIM31901I SYSMOD XXxxxx DOES NOT SPECIFY xxxxxx ON THE PRE OR SUP OPERAND.
search cancel

GIM31901I SYSMOD XXxxxx DOES NOT SPECIFY xxxxxx ON THE PRE OR SUP OPERAND.

book

Article ID: 33268

calendar_today

Updated On:

Products

Disk Backup and Restore - MVS DISK BACKUP AND RESTORE- ADD-ON OPTIO DISK BACKUP AND RESTORE

Issue/Introduction

When applying maintenance and receiving the following error messages:                     
GIM38201E ** THERE IS A MODID ERROR FOR PARM ENTRY PARMEDIT IN SYSMOD XXxxxx.               
GIM31901I    SYSMOD XXxxxx DOES NOT SPECIFY xxxxxx ON THE PRE OR SUP OPERAND. xxxxxx IS THE RMID FOR PARM PARMEDIT   
             THAT IS CURRENTLY INSTALLED.                                                    
GIM22601I    APPLY PROCESSING FAILED FOR SYSMOD XXxxxx.

Environment

Release: Diskā„¢ Backup and Restore

Cause

The cause is having a SYSMOD or USERMOD that is not on the PRE or SUP of the PTF being applied.

Resolution

Restoring the SYSMOD or USERMOD prior to applying the needed PTF and then re-applying the SYSMOD or USERMOD as needed.