Smarts ESM: ESM is not raising a PoweredOff alert for a VM which is down but IP shows an Unresponsive alarm.
search cancel

Smarts ESM: ESM is not raising a PoweredOff alert for a VM which is down but IP shows an Unresponsive alarm.

book

Article ID: 332227

calendar_today

Updated On:

Products

VMware Smart Assurance

Issue/Introduction

Symptoms:




An issue was reported where a Host had the 'isVMHost' set to false, due to the fact that the vmIPAddress discovered by ESM was an address not directly accessible for Smarts. The Host was imported to IP/ESM via Mgmt-NAT IPAddress

This resulted in only one Minor Unresponsive notification due to the missing correlation.

Environment

VMware Smart Assurance - SMARTS

Resolution

A code workaround was implemented to generate the PoweredOff notification but this is not an offfical GA EMC fix and can be offered only on an as-is basis with no support.

After the work around was implemented in 'esm-post.asl', ESM is now raising the PoweredOff notification.

Making the IP available in smarts would also work but that may not be feasible