Symptoms:
Smarts converts voltage to millivoltage eg 12V to 0.012
Environment
VMware Smart Assurance - SMARTS
Cause
An incorrect certification
Resolution
A fix is being prepared however the following change to the certification will suffice as a workaround:
Change the existing cert:
#Cisco ASR 1013 Router
.1.3.6.1.4.1.9.1.1166 {
TYPE = Router
VENDOR = Cisco
MODEL = ASR1013
CERTIFICATION = CERTIFIED
CONT = Cisco-Router-Entity
NEIGHBOR = Cisco-Cdp
HEALTH = Cisco-Router-CRS-EntSensor
INSTRUMENTATION:
Environment = CiscoEntitySensor:DeviceID
CPU/Memory = CiscoRouter:DeviceID
Card-Fault = CiscoEntityFRU
Interface-Fault = MIB2
Interface-Performance = MIB2
}
To:
#Cisco ASR 1013 Router
.1.3.6.1.4.1.9.1.1166 {
TYPE = Router
VENDOR = Cisco
MODEL = ASR1013
CERTIFICATION = CERTIFIED
CONT = Cisco-Router-Entity
NEIGHBOR = Cisco-Cdp
HEALTH = Cisco-Router-CRS-EntSensor
INSTRUMENTATION:
Environment = CiscoEntityFRU:DeviceID <<<<<<< this is the fix
CPU/Memory = CiscoRouter:DeviceID
Card-Fault = CiscoEntityFRU
Interface-Fault = MIB2
Interface-Performance = MIB2
}