Smarts IP 9.2: Temperature Sensor is OutOfRange in UCS B-Series
book
Article ID: 332075
calendar_today
Updated On:
Products
VMware Smart Assurance
Issue/Introduction
Symptoms:
Unneeded Temperature Sensor OutofRange alerts are received for UCS B-Series devices in Smarts IP 9.2 and Smarts Server Manager 9.2.
The following screenshots show the Smarts SAM Notification generated for this issue and the Temperature Sensor Containment View in Smarts IP.
Smarts SAM Notification of TemperatureSensor OutOfRangeTemperature Sensor Containment View in Smarts IP
Environment
VMware Smart Assurance - SMARTS
Cause
This issue can be seen with any of the UCS-B series devices because of the settings configured for the Smarts IP UseMIBThresholds.
Resolution
If you encounter this issue, do the following:
-
In Smarts IP Polling and Thresholds, select the Thresholds tab and navigate to System Resource Groups > Other Systems > Settings.
-
Select Environment and change the value for the UseMIBThresholds attribute value (shown below) to from "true" to "false":
-
Click reconfigure.
Additional Information
The image files for the above screenshots are attached with this article.