Smarts OTM: Is it possible for OTM to alarm for both Signal Degrade (SD) and Loss of Signal (LOS) simultaneously?
book
Article ID: 331873
calendar_today
Updated On:
Products
VMware Smart Assurance
Issue/Introduction
Symptoms:
A customer wants to know if Smarts OTM canĀ alarm for both Signal Degrade(SD) and Loss of Signal(LOS) simultaneously?
Environment
VMware Smart Assurance - SMARTS
Cause
One alarm seems to clear the other and they are never seen simultaneously
Resolution
For the same Object/Interface both Signal Degrade(SD) and Loss of Signal(LOS) cannot be raised simultaneously. If SD is raised, then LOS will be cleared and vice-versa. This is the expected behavior of the product