Smarts NCM: Canopy Cambium PMP450 device pull fails when more than one device is selected
book
Article ID: 331275
calendar_today
Updated On:
Products
VMware Smart Assurance
Issue/Introduction
Symptoms:
Canopy Cambium PMP450 device pull running config is successful if pull is attempted on one or two devices at a time, but fails if pull config is attempted on more devices. Running config is failing to pull with below error in the GUI:
Pulling configuration file 'running' for IDX xxx with mechanism SNMP/TFTP and SNMPV3 File uploaded to tftp server using SNMP/TFTP Empty config file running Pull of running failed Unable to pull config file: running
Environment
VMware Smart Assurance - NCM
Cause
It is observed that all individual pull jobs from canopy driver are trying to create configuration file with same name.
Example from commmgr.log:
Dec 07 05:11:00 1098864384/pull(21828026)#4: Touching file: /tftpboot/config.json Dec 07 05:47:20 -2120317184/pull(21829332)#4: Touching file: /tftpboot/config.json
Resolution
This issue is fixed in DSR 23 HF3 and above. Refer the attached DSR 23 HF3 release notes, page.7 for details of the issue and fix.