Issue/Introduction

Symptoms:




Smarts NCM Session log contains an exception similar to the following:

Mar 05 15:10:26 -1870653120/ssh#1: ::getCurrentState - State match:[1001][^[^\s#]+# *$][XX-XXXX-XX-XXX-13#]
Mar 05 15:10:26 -1870653120/ssh#1: ======== cacheSession(): idx(2431) sid(0) state(5003) user(S-Ionix-NCM-L15) mech(3) timeout(60)
Mar 05 15:10:26 -1870653120/ssh#1: SND>vlan database
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>vlan database
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>% Warning: It is recommended to configure VLAN from config mode,
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>  as VLAN database mode is being deprecated. Please consult user
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>  documentation for configuring VTP/VLAN in config mode.

Smarts NCM console user interface displays an error similar to the following:
 
[vlan text] Action completed with a warning...
Pulling configuration file 'vlan text' for IDX 2712 with mechanism SSH
Device does not implement 'vlan database'; pull of vlan text failed!
 
Configuration file 'vlan text' for IDX 2712 completed with a warning with error code 'Unspecified Error' in 1 seconds


Environment

VMware Smart Assurance - NCM

Cause

As shown in the above logs, Smarts NCM is sending a vlan database command to the device, but when device is trying to execute the command it is giving the above warning message. Because the command 'vlan database' is not implemented by the device, the vlan database command must be run by the user for the affected devices. However, there are certain Cisco IOS releases which do not support this command.

Resolution

If you require this functionality, please raise a product enhancement request with EMC.