Symptoms:
Smarts NCM Session log contains an exception similar to the following:
Mar 05 15:10:26 -1870653120/ssh#1: ::getCurrentState - State match:[1001][^[^\s#]+# *$][XX-XXXX-XX-XXX-13#]
Mar 05 15:10:26 -1870653120/ssh#1: ======== cacheSession(): idx(2431) sid(0) state(5003) user(S-Ionix-NCM-L15) mech(3) timeout(60)
Mar 05 15:10:26 -1870653120/ssh#1: SND>vlan database
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>vlan database
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100>% Warning: It is recommended to configure VLAN from config mode,
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100> as VLAN database mode is being deprecated. Please consult user
Mar 05 15:10:27 -1870653120/ssh#1: RCV-100> documentation for configuring VTP/VLAN in config mode.
Smarts NCM console user interface displays an error similar to the following:
[vlan text] Action completed with a warning...
Pulling configuration file 'vlan text' for IDX 2712 with mechanism SSH
Device does not implement 'vlan database'; pull of vlan text failed!
Configuration file 'vlan text' for IDX 2712 completed with a warning with error code 'Unspecified Error' in 1 seconds