The problem has been addressed through internal ticket ID
#69194.The fix for this issue is found on the following VMware Edge releases:
- On release 4.2.2, this fix is included with the R422-20220419-GA which was released on 04-20-2022 and all later Edge builds in this release train.
- On release 4.3.1, this fix is included with the 4.3.1 Edge release R431-20211208-GA and all subsequent releases like 4.5.0 and 5.0.0.0.
Workaround:
No workaround is available.
On an Edge not using software with the fix for #69194, any move of a live USB modem from one USB port to a different USB port should only be done in a maintenance window that minimizes the potential impact of a disruption of customer traffic.
If the Edge is powered off prior to moving a USB modem to a different USB port, this would avoid the Dataplane Service failure and resulting system restart, but will result in additional downtime while the Edge is powered off and before it fully comes back from boot up after being powered on again.