DLR fails to resolve mac addresses of VMs on differents ESXi hots if uplinks on vDS are named in Japanese.
search cancel

DLR fails to resolve mac addresses of VMs on differents ESXi hots if uplinks on vDS are named in Japanese.

book

Article ID: 327349

calendar_today

Updated On:

Products

VMware NSX Networking

Issue/Introduction

Symptoms:
  • Fail to ping between VMs on different ESXi hosts via DLR.
  • "net-vdr -C -l" command shows that uplinks' names have non-English characters:
DvsName VdrPort NumLifs VdrVmac
------- ------- ------- -------
DSwitch-Mgmt vdrPort 2 02:50:56:56:44:52
    Vdr Switch Port: 67108875
    Teaming Policy: SrcPortId Hashing
    Uplink : アップリンク 2(67108869): 00:50:56:e7:47:50(Non-team member) 
    Uplink : アップリンク 1(67108866): 00:50:56:e7:64:d4(Non-team member)
  • esxtop shows that vdr-vdrPort is void:
   PORT-ID USED-BY TEAM-PNIC DNAME PKTTX/s MbTX/s PSZTX PKTRX/s MbRX/s PSZRX %DRPTX %DRPRX
  67108865 Management n/a DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  67108866 vmk0 vmnic1 DvsPortset-1 1.94 0.00 147.00 0.39 0.00 76.00 0.00 0.00
  67108867 vmnic1 - DvsPortset-1 1.94 0.00 147.00 11.65 0.01 158.00 0.00 0.00
  67108868 Shadow of vmnic1 n/a DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  67108869 vmnic0 - DvsPortset-1 1.17 0.00 238.00 12.43 0.01 149.00 0.00 0.00
  67108870 Shadow of vmnic0 n/a DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  67108872 vmk1 vmnic0 DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  67108873 vdr-vdrPort void DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Cause

NSX Manager cannot handle with Japanese characters when sending vxlan configurations to ESXi hosts.

Resolution

This issue is fixed in NSX 6.4.2.

Workaround:
Create uplinks with English characters.