Certain HPE NVMe Solid State Drive models fails after 4700 hours of operation
search cancel

Certain HPE NVMe Solid State Drive models fails after 4700 hours of operation

book

Article ID: 326653

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

Symptoms:

HPE NVMe SSDs experience unexpected failures after 4700 hours of operation (i.e, 6 to 7 months).

vSAN Disk groups goes offline.


Impacted HPE NVMe SSD models:-

  HPE Model Number

HPE SKU

HPE SKU DESCRIPTION

  MO001600KWVUU

  P13699-B21,
  P13699-H21,
  P13699-K21

HPE 1.6TB NVMe x4 Lanes Mixed Use SSD

  MO001600KWVUU

  P18140-B21

HPE DX 1.6TB NVMe x4 Lanes Mixed Use SFF (2.5in) SCN 3yr Wty Digitally Signed Firmware FIO SSD

  VO002000KWVVC

  P13695-B21,
  P13695-H21,
  P13695-K21

HPE 2TB NVMe x4 Lanes Read Intensive SSD

  VO002000KWVVC

  P18145-B21

HPE DX 2TB NVMe x4 Lanes Read Intensive SFF (2.5in) SCN 3yr Wty Digitally Signed Firmware FIO SSD

  MO003200KWVUV

  P13701-B21,
  P13701-H21,
  P13701-K21

HPE 3.2TB NVMe x4 Lanes Mixed Use SSD

  MO003200KWVUV

  P18142-B21

HPE DX 3.2TB NVMe x4 Lanes Mixed Use SFF (2.5in) SCN 3yr Wty Digitally Signed Firmware FIO SSD

  VO004000KWVUR

  P13697-B21,
  P13697-H21,
  P13697-K21

HPE 4TB NVMe x4 Lanes Read Intensive SSD

  VO004000KWVUR

  P18149-B21

HPE DX 4TB NVMe x4 Lanes Read Intensive SFF (2.5in) SCN 3yr Wty Digitally Signed Firmware FIO SSD

  MO006400KWVVA

  P13703-B21,
  P13703-H21,
  P13703-K21

HPE 6.4TB NVMe x4 Lanes Mixed Use SSD

 

Environment

VMware vSAN 6.x
VMware vSAN 7.x

Resolution

Upgrade the drive firmware to version 4ICRHPK3, which HPE has released to prevent this issue.

If the failure occurs, the SSD might not recover even after the firmware upgrade.

For more information and affected disks/server models see the below advisories:
Bulletin: (Revision) HPE NVMe Solid State Drives - Critical Firmware Upgrade Required for Certain HPE NVMe Solid State Drive Models to Prevent Drive Failure After 4700 Hours of Operation

Please engage VMware and HPE support if additional assistance is required to get the environment back into a healthy state.