2022-04-14T10:11:58.593Z ERROR L2HostConfigTaskExecutor2 TransportNodeAsyncServiceImpl 4934 FABRIC [nsx@6876 comp="nsx-manager" errorCode="MP8700" level="ERROR" subcomp="manager"] host switch apply operation failed: [invalid dvs parameter :[50 1d 00 40 3f c0 6b 24-a0 ec d8 07 9a 83 48 44|RegionA01-DVS7|Test|8900|e6bb76b5-c15f-474f-b3ef-72fd2cd80934
NSX-T does not support the use of special characters in the DVS name
There is currently no fix for this issue
Remove all special characters from DVS name and attempt the host preparation again