Issue/Introduction
Symptoms:
You have multiple blueprints from the same content source After releasing, not all blueprints are found
Environment
VMware vRealize Suite Lifecycle Manager 8.x
Cause
This issue occurs when a parallel update of the vRA content source overwrites other blueprint data causing only the latest blueprint to be visible.
Resolution
This issue is resolved in vRealize Suite Lifecycle Manager 8.8.
See the Workaround below for additional information.
Workaround:
Take a snapshot of the vRSLCM appliance SSH / PuTTy into the vRSLCM appliance Run the following command to change directories
cd /opt/vmware/vlcm/blackstone/configuration/content-config
Open the file bootstrap_content_category_config.json Change the minConcurrentPipelinesPerEndpoint and maxConcurrentPipelinesPerEndpoint value in the list where id is Automation-v7 and Automation-v8 After changing the values, restart the service with the command
systemctl restart blackstone-spring