Network filter errors, No placement exists, or enumeration failures when using VMware Aria Automation
search cancel

Network filter errors, No placement exists, or enumeration failures when using VMware Aria Automation

book

Article ID: 325838

calendar_today

Updated On:

Products

VMware Aria Suite

Issue/Introduction

Symptoms:
  • NSX-T Transport Zone Policy API supports any string as ID:
    • In cases where IDs are in GUID format, get hosts and clusters does not fail but does not return results.
      • You are attempting to provision a machine from VMware Aria Automation with NSX-T integration and a failure is encountered similar to one of the below errors:
        • Reason: network filter: host does not conform with the network configuration
        • No placement exists that satisfies all the requested requirements
    • Data collection errors can be found in /service-logs/prelude/provisioning-app-xxxxxx similar to:

      java.lang.IllegalStateException: Identifier does not contain an UUID
      


Environment

VMware Aria Automation 8.x

Cause

VMware Aria Automation NSX-T Policy Cloud Account enumeration of transport zones and segments is failing and/or skipped due to incompatibility in transport zone IDs.

Resolution

This issue is resolved in VMware Aria Automation 8.13.1 and above.