In VMware NSX for vSphere 6.x, virtual machines located behind an NSX Edge Services Gateway (ESG) deployed using vRealize Automation 6.x multi-machine blueprint are unreachable
book
Article ID: 325464
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
Symptoms:
Connectivity to virtual machines located behind an VMware NSX for vSphere 6.x Edge Services Gateway (ESG) fails
Running the show interface command for the vNIC interfaces on the NSX Edge reports entries similar to:
2: vNic_0: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc pfifo_fast state DOWN qlen 1000 link/ether X:X:X:X:X:X brd ff:ff:ff:ff:ff:ff inet x.x.x.x/24 scope global vNic_0 5: vNic_1: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc pfifo_fast state DOWN qlen 1000
Environment
VMware NSX for vSphere 6.4.x VMware NSX for vSphere 6.1.x VMware NSX for vSphere 6.3.x VMware NSX for vSphere 6.2.x
Cause
The line protocol down on an Edge vNIC interface indicates that the interface is disconnected from the back-end layer-2 switch. This issue is known to occur when the Edge VM is deployed before host preparation completes or the switch completes initialization.
Resolution
Use the following steps to troubleshoot this issue:
Investigate a VXLAN or host preparation configuration issues. For more information, see: