Enabling Intel FlexRAN with CPU C6 State in Telco Cloud Platform (TCP) RAN 4.0
search cancel

Enabling Intel FlexRAN with CPU C6 State in Telco Cloud Platform (TCP) RAN 4.0

book

Article ID: 325359

calendar_today

Updated On:

Products

VMware

Issue/Introduction

Intel Package C-State C6 is supported in TCP-RAN 4.0.

This article provides the prerequisites and procedure to enable C6 state in a Nodepool virtual machine.


Resolution

Pre-requisites
Telco Cloud Automation: 3.1.0.23586009 or later
BYOI: 23561559 or later
Server: Dell XR11, 64 Icelake CPU(s) Intel(R) Xeon(R) Gold 6338N, 512 GB memory
ESXi: 8.0.2 23424722 (Hot Patch build with C6 State support) or later


Follow the steps below to enable C6 state in a Nodepool virtual machine.

  1. In TCA 3.1.0, create a nodepool VM from the given BYOI template (photon-5-kube-v1.28.4-vmware.1).
  2. Instantiate the CNF (Here testnf is used as an example):
    1. Instantiate the Network Function with the newly updated NF CSAR.
    2. Modify the CSAR to enable C6 State from the TCA UI go to Catalog > Network Function
    3. Select a Network Function, click on the 3 dots and select Edit.
    4. In the Infrastructure Requirements section expand Kernel Arguments and make the following changes:
      Remove idle=halt
      Change intel_idle.max_cstate to 6
      Add cpuidle.off=0                                                                                                                                                                                                                                                                            
      image.png
    5. Create a text file (e.g. testnf-c6-tuned.conf) with the following contents:
      #Enable C6 State
      [cpu]
      force_latency=-
    6. Go to the Resources section and upload the text file to Artifacts/scripts/ and save as /usr/lib/tuned/c6/tuned.conf                                                     image.png
    7. Once uploaded, set the Tuned Profiles under Infrastructure Requirements to realtime,c6.                                                                                                                                               image.png
    8. Save the testnf CSAR by selecting either Update Package or Save as New.
  3. Instantiate the Network Function with the newly updated NF CSAR.
  4. After the Network Function instantiated, the virtual machine’s Advanced Parameters should show the cpuid.5.0.edx attribute.
  5. Running turbostat on the VM shows C6 is enabled:                                                                                                                                                                                                                                                       A screenshot of a computer  Description automatically generated