Database Analyzer (IMS Tools) Database Analyzer for IMS for z/OS DATABASE MANAGEMENT SOLUTIONS FOR IMS FOR Z/OS

Issue/Introduction

When analyzing a database that is online, Database Analyzer for IMS fails with messages ITKC200E, ITKC201E and IDI2502E. 

Resolution

When analyzing a database that is online, it is recommended that you bypass database authorization by specifying control statement AUTH=NO in the control cards.

For example:

FUNCTION=ANALYZE,                            
DBDNAME=dbname,
DBRC=YES,
AUTH=NO
With AUTH=NO specified, Database Analyzer will not perform any DBRC database authorization and this avoid any potential authorization failures.