LACP and VDR Port Teaming policy fails in ESXi 6.7.x with NSX-T Data Center 2.4
book
Article ID: 325141
calendar_today
Updated On:
Products
VMware NSX
VMware vSphere ESXi
Issue/Introduction
Symptoms:
- LACP is down between N-VDS on Transport Nodes and Physical SW.
- Ping connectivity across VM-SR across same LS is broken.
- LACP teaming policy on the VDR port was incorrectly set.
- Issue is only observed when using NSX-T 2.4.0, 2.4.1, 2.4.2 with ESXi 6.7 hosts.
Environment
VMware NSX-T Data Center 2.x
VMware NSX-T Data Center
VMware vSphere ESXi 6.7
Resolution
This issue is resolved in:
VMware NSX-T Data Center 2.4.3, available at
VMware Downloads .
VMware NSX-T Data Center 2.5, available at
VMware Downloads.
Workaround:
There is no workaround when using ESXi 6.7 hosts.
Additional Information
This issue does not affect ESXi 6.5 hosts.
Impact/Risks:
Loss of connectivity across VMs and Service connections (Service Routers, etc).