Generate of Endevor Processor failing with ASMA057E UNDEFINED OPERATION CODE
search cancel

Generate of Endevor Processor failing with ASMA057E UNDEFINED OPERATION CODE

book

Article ID: 32510

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

On generation of an Endevor processor received the following message;

** ASMA057E UNDEFINED OPERATION CODE 
** ASMA435I RECORD 5 IN SYS22137.T103000.RA000.XXXXXXXX.XXXXX.XXX ON VOLUME: XXXXXX

** ASMA057E UNDEFINED OPERATION CODE 
** ASMA435I RECORD 6 IN SYS22137.T103000.RA000.XXXXXXXX.XXXXX.XXX ON VOLUME: XXXXXX

 

 

Environment

Release : All Supported Releases

Resolution

The first place to check is to see what is defined as the macro library in the C1DEFLTS table.   This can be found by going into foreground Endevor selecting the OPTION 1 for DISPLAY and then sub option 3 for SITE.

This will display the first page of the Site Information from C1DEFLTS panel; hit enter to go the second page - the below panel should be displayed: 

https://api-broadcom-ca.wolkenservicedesk.com/attachment/get_attachment_content?uniqueFileId=TFHBXSIE1zdjPfE3gubeOw==  

 

The ENDEVOR.CSIQOPTN library is where the Endevor macros used in the generation of Endevor processors are stored.  If the MACRO library is pointing to anything other than the CSIQOPTN library that is delivered with the prodcut, the generate of any processor will fail.