Symptoms:
If a customer performs an SNMP query for a VMware SD-WAN Edge interface configured to use DPDK, a customer may experience a longer than expected delay in getting results.
VMware SD-WAN
VMware SD-WAN by VeloCloud
The delay is caused by a back-end script for collecting the interface data that is not properly optimized.
This is caused by known issue #122426
This issue is fixed in Releases R452-20231025-GA and 5.2.2
5.2.2 Release Notes - https://techdocs.broadcom.com/us/en/vmware-sde/velocloud-sase/vmware-velocloud-sd-wan/5-2/vmware-velocloud-sdwan-522-release-notes.html
For information on how to upgrade please check the following article: https://knowledge.broadcom.com/external/article/312384/vmware-velocloud-sdwan-software-upgrade.html
Workaround:
N/A