'connect timeout' error observed while deploying Edge from NSX UI
book
Article ID: 324597
calendar_today
Updated On:
Products
VMware NSXVMware vSphere ESXi
Issue/Introduction
When attempting to deploy a new NSX Edge Node from UI, we will see a "connect timeout" error.
In the /var/log/cm-inventory/cm-inventory.log on NSX manager, you will find entries similar to:
2023-04-03T12:05:25.785Z ERROR Thread-28 ResourcePoolOperation - - [nsx@6876 comp="nsx-manager" errorCode="MP40409" level="ERROR" subcomp="cm-inventory"] Ovf deploy failed while deploying vmdk http://#.#.#.#:8080/repository/3.0.1.1.0.16556497/Edge/ovf/nsx-edge.vmdk on vc 52######-####-####-####-##########12 for vm: vm-1####8 with type error connect timed out java.net.SocketTimeoutException: connect timed out
In the /var/log/syslog on NSX manager, you will see entries similar to:
<182>1 2023-04-03T12:05:25.875Z NSX 30893 FABRIC [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] Updating the deploymentProgressState for deploymentUnitInstance: DeploymentUnitInstance [ id=cb######-####-####-####-##########1a, deploymentUnitId=e2######-####-####-####-##########9d, hostId=null, entityId=vm-1####8, runningVersion=null, deploymentProgressState=DEPLOYMENT_FAILED, deploymentGoalState=ENABLED, internalLastKnownOSVersion=null, agentId=null, errorId=0, errorMessage=connect timed out] to DEPLOYMENT_FAILED:connect timed out
<179>1 2023-04-03T12:05:25.877Z NSX 30893 FABRIC [nsx@6876 comp="nsx-manager" errorCode="MP16019" level="ERROR" subcomp="manager"] [entId=Node/e4######-####-####-####-##########e1] Edge node deployment failed due to errorDetails='connect timed out'
In the vCenter, the import task times out.
In the /var/log/vmware/vpxd/vpxd.log on vCenter, you will find entries similar to:
2023-04-03T17:40:23.835+05:30 info vpxd[22536] [Originator@6876 sub=VAppImport opID=66####d5-01] Import task timed out 2023-04-03T17:40:23.835+05:30 info vpxd[22536] [Originator@6876 sub=MoHttpNfcLease opID=66####d5-01] Releasing HTTP-NFC ticket 2023-04-03T17:40:23.838+05:30 info vpxd[22536] [Originator@6876 sub=MoHttpNfcLease opID=66####d5-01] Task aborted 2023-04-03T17:40:23.840+05:30 error vpxd[22536] [Originator@6876 sub=VAppImport opID=66####d5-01] Caught exception while importing VM: N3Vim5Fault8Timedout9ExceptionE(Fault cause: vim.fault.Timedout
Note: The preceding log excerpts are only examples. Date, time, and environmental variables may vary depending on your environment.
Environment
VMware NSX VMware NSX-T Data Center
Cause
During Edge node deployment, NSX Manager will connect to the ESXi host where Edge will reside for transferring the required files.
This issue occurs when NSX manager is unable to communicate with ESXi host on TCP port 443 for transferring the edge vmdk files.
Resolution
NSX requires TCP port 443 to be open between NSX manager and ESXi hosts for management and provisioning connections.
Log in to the NSX Manager CLI as root.
Test connectivity to the target ESXi host management IP on port 443: nc -zv <ESXi-IP> 443
If the connection fails or times out, identify and disable any firewall rules or Layer 3 gateway ACLs blocking TCP port 443 between the NSX Manager and the ESXi host.
Once the nc -zv command returns a "succeeded" message, retry the Edge deployment from the NSX UI.
Output of a successful connection:
root@324:~# nc -zv #.#.#.# 443 Connection to #.#.#.# 443 port [tcp/https] succeeded!
Workaround:
If port 443 needs to remain blocked, deploy the edge from the vCenter using an edge ova and manually register it with the NSX Manager. For more information, refer NSX Documentation.