Vmnic transient failure recovery due to watchdog timeout
book
Article ID: 324514
calendar_today
Updated On:
Products
VMware vCenter ServerVMware vSphere ESXi
Issue/Introduction
Summary
A vmnic recovered from a transient failure due to watchdog timeout.
Example
The following is a typical message:
Uplink vmnic0 has recovered from a transient failure due to watchdog timeout
You may see one or both of the following errors in the logs:
[esx.problem.net.vmnic.watchdog.reset] Uplink vmnic13 had recovered from a transient failure due to watchdog timeout. [vob.net.uplink.watchdog.timeout] Watchdog timeout occurred for uplink vmnic13.
Impact
Frequent warnings (more than a few times per hour), might indicate a network adapter hardware problem.
Resolution
This event is informational only. Occasional reset warnings can be safely ignored.