Intermittent packet loss after Edge cutover during an NSX-v to NSX-T migration
book
Article ID: 324250
calendar_today
Updated On:
Products
VMware NSX Networking
Issue/Introduction
Symptoms:
NSX 3.2.x, 4.x
NSX-v to NSX-T migration using Migration Coordinator
Intermittent packet loss is observed after completing the Edge migration phase
The impacted VMs are still running on NSX-v hosts
There are no log errors associated with this issue
Environment
VMware NSX-T Data Center VMware NSX-T Data Center 4.x VMware NSX-T Data Center 3.x
Cause
After Edge migration phase, VMs on NSX-v hosts are routed via the NSX-T DR. Due to incorrect handling by the NSX-T DR, ARP resolution is impacted which causes intermittent packet loss.
Resolution
This issue is resolved in NSX versions 3.2.3.1 and 4.1.1.
Workaround: Proceed and complete the Host migration after which this issue will be resolved.