Bare Metal Edge with Mellanox NIC experiences BGP flapping
book
Article ID: 324249
calendar_today
Updated On:
Products
VMware NSX Networking
Issue/Introduction
Symptoms:
NSX 3.2.x/4.x
Bare Metal Edge with Mellanox ConnectX-4 or ConnectX-5 NICs
BGP flapping is observed
Data plane service on the Edge crashes /var/log/syslog
2023-08-09T02:46:02.699Z NSX 4547 - [nsx@6876 comp="nsx-edge" subcomp="node-mgmt" username="root" level="WARNING" eventFeatureName="infrastructure_service" eventType="edge_service_status_changed" eventSev="warning" eventState="On"] The service dataplane changed from STARTED to CRASHED.
On the Edge /var/dump has a datapath core file with a name similar to core.dp-fp
Environment
VMware NSX-T Data Center 3.x VMware NSX-T Data Center 4.x VMware NSX-T Data Center
Cause
This issue occurs due to a failure during packet processing by the NIC driver.
Resolution
This is a known issue impacting NSX-T Bare Metal Edges.