We are installing Datacom/AD and receive this error when trying to start the Multi-user (MUF) for the first time:
DB00205E - MULTI-USER ERROR 1211 CXXNAME CXXPROD VS CXX0NAME
What does this error mean, and how do we correct it?
Component : Datacom/AD
Component : Datacom/DB
The last part of the DB00205E message gives the clue for this problem, which is that there is a mismatch of the CXX names you have specified for this MUF installation:
CXXNAME xxxxxxxx VS yyyyyyyy
For example, given the message DB00205E - MULTI-USER ERROR - 1211 CXXNAME CXXPROD VS CXX0NAME:
rIn the INSTJCL customization job AXCUSNEW (Datacom/AD) or BDCUSNEW (Datacom/DB), you have coded "CXXPROD" as the value for "CXXNAME=" in the DBSIDPR macro, but you coded "CXXNAME=CXX0NAME" in the job that actually initialized the CXX (AXNEW01 for Datacom/AD, BDNEW01 for Datacom/DB).
To correct this, rerun the AXNEW01 or BDNEW01 job, and specify CXXNAME=* on the INIT AREA=CXX command (this is how the product is delivered). For example:
INIT AREA=CXX,DATACOM=AD,CXXNAME=*
"*" means the CXX name will be taken from the DBSIDPR (in this example, it would be CXXPROD)
To find out what is specified in your DBSIDPR module, run a DBUTLTY job (there are several examples of this step in the INSTJCL PDS) with the following input:
//SYSIN DD *
SET OPTION1=ON-ERROR-CONTINUE
SET OPTION1=DUMPSID=DBSIDPR
SET OPTION1=DUMPPGM=DBSIDPR
/*
Further information on the DBSIDPR parameters can be found in the documentation section titled "Modifying DBSIDPR Parameters."
As always, please contact Broadcom support for Datacom if you have further questions.