Issue/Introduction

The purpose of this article is to resolve the message / error when discovering various type of devices including UPS devices.

Environment

Smarts - 10.1.x
TCSA - 2.x
Smarts-DM - 2.x

Cause

The error is usually displayed, because the agent determined that the packets timeliness was not within the threshold.

Resolution

  • Try restarting the SNMPV3 agent. A restart of the SNMP V3 packet exchange will usually resolve the problem.
  • If restarting the SNMP agent does not resolve it, try changing the SNMP timeout setting to 3000ms on the agent.
  • Do another discovery to re-synchronize.

    Workaround:
    Updating the agent timeout setting to 3000ms and restarting the agent will usually resolve this issue

Note: This is not Smarts issue, recommendation suggested in this article to be discussed with the device owners / network administrators.