ESXi host fails with PSOD "Fatal error" with Intel E810 vmnic.
search cancel

ESXi host fails with PSOD "Fatal error" with Intel E810 vmnic.

book

Article ID: 323028

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • Intel E810 vmnic with icen driver is installed on ESXi.
  • ESXi Host fails with PSOD with "Fatal error"
  • The scenarios above may lead to PSOD with the following information:
IPMI log:
 
Record:2:
   Record Id: 2
   When: YYYY-MM-DDTHH:MM:SS
   Event Type: 111 (Unknown)
   SEL Type: 2 (System Event)
   Message: Assert + Critical Interrupt Bus Fatal Error
   Sensor Number: 24
   Raw:
   Formatted-Raw: 02 00 02 3a 08 d3 63 b1 00 04 13 18 6f XX XX XX
  • PCI list shows the PCI id relates to E810 vmnic:
  vmnic10  0000:b1:00.0     Up    25000  Full    9000  icen    1.9.8.0         4.00 0x800118b3 21.5.9  b4:83:51:03:XX:XX  8086  159b  8086  0002  Intel(R) Ethernet Controller E810-XXV for SFP
 
  vmnic11  0000:b1:00.1     Up    25000  Full    9000  icen    1.9.8.0         4.00 0x800118b3 21.5.9  b4:83:51:03:YY:YY  8086  159b  8086  0002  Intel(R) Ethernet Controller E810-XXV for SFP

 

  • In some customer's environments, IPMI log shows as below
    Record Id  When                 Event Type     Message
 
    ---------  ----                 ----------     -------
 
    292        YYYY-MM-DDT09:01:25  111 (Unknown)  Assert + Critical Interrupt Bus Uncorrectable error
 
    293        YYYY-MM-DDT09:01:44  111 (Unknown)  Assert + System Event Undetermined system hardware failure
 
    294        YYYY-MM-DDT09:04:48  111 (Unknown)  Assert + Slot/Connector Fault Status

 

Environment

VMware vSphere 7.0.x

Cause

'Critical Interrupt Bus Fatal/Uncorrectable error' is obviously a hardware issue, not VMware software part.

Resolution

Involving Intel hardware vendor with above symptoms is recommended.

Workaround:

No workaround.

Intel vendor is still investigating the issue. Pending on Intel's output.