Issue/Introduction
- Pre upgrade check fails for Management Plane (MP) due to Password Expiration alarm in open state.
- Resolve/Acknowledge Alarms option results in "Failed to update status for the selected alarm"
- On the Manager log (
/var/log/proton/nsxapi.log
(as root) has logging similar to these examples:
2021-01-28T13:45:22.508Z INFO pool-117-thread-1 ResolvedAlarmsProcessor - MONITORING [nsx@6876 comp="nsx-manager" level="INFO" subcomp="monitoring"] processResolvedAlarms: deleting 0 RESOLVED alarms older than 8 days 2021-01-
28T13:45:22.645Z INFO pool-117-thread-1 MonitoringSyncProcessor - MONITORING [nsx@6876 comp="nsx-manager" level="INFO" subcomp="monitoring"] invokeTargetedSync: requesting sync for alarm ########-####-####-####-fa2ad3e937fa , endpoint: ########-####-####-####-c5f183e6806d, feature: 4, eventType: 1, entity 00000000-0000-0000-0000-000000000000, node: ########-####-####-####-c5f183e6806d, source: napi_password_management as sync = true
2021-01-28T13:45:22.645Z INFO pool-45-thread-1 MonitoringSyncService - MONITORING [nsx@6876 comp="nsx-manager" level="INFO" subcomp="monitoring"] MonitoringSyncService: initiating sync request endpointId ########-####-####-####-c5f183e6806d 2021-01-28T13:45:22.946Z INFO pool-45-thread-1 MonitoringSyncService - MONITORING [nsx@6876 comp="nsx-manager" level="INFO" subcomp="monitoring"] Built Sync Request entityId: 00000000-0000-0000-0000-000000000000, eventTypeId: 1, featureId: 4, sourceId: napi_password_management
2021-01-28T13:45:32.645Z WARN pool-117-thread-1 MonitoringSyncProcessor - MONITORING [nsx@6876 comp="nsx-manager" level="WARNING" subcomp="monitoring"] initiateSyncRequest: unexpected error invoking sync on feature 4 eventType 1 node ########-####-####-####-c5f183e6806d endpoint ########-####-####-####-c5f183e6806d source napi_password_management entity 00000000-0000-0000-0000-000000000000: null
2021-01-28T13:45:32.646Z ERROR pool-45-thread-1 MonitoringSyncService - MONITORING [nsx@6876 comp="nsx-manager" errorCode="MP701026" level="ERROR" subcomp="monitoring"] Sync failure CANCELLED
Environment
VMware NSX-T Data Center
VMware NSX-T Data Center 3.x
Resolution
This issue is resolved in VMware NSX 3.0.3
This issue is resolved in VMware NSX 3.1.2
This issue is resolved in VMware NSX 3.2.0
Workaround:
To workaround this issue, please contact Broadcom Support.