To learn more about firstboot issues see: Firstboot Failed during Install, Deployment, Upgrade, or Migration in vCenter Server and vCenter Server Appliance 6.7
To collect a log bundle or review log files for a vCenter Server Appliance install, upgrade, or migration issues reference Collecting Logs for Troubleshooting a vCenter Server Installation or Upgrade The relevant logs will be on the newly deployed appliance.
firstbootStatus.json contains the following: "failedSteps": "sms_spbm_firstboot"
sms_spbm_firstboot.py_####_stderr.log contains the following: VMware vSphere Profile-Driven Storage Service failed to start
fbInstall.json shows an unexpected time discrepancy between the start time and end time. This could be a large jump forward or backward in time. For example:
In the first example, although the upgrade may have failed in twenty minutes, the logs indicate a five hour difference between the start and end time. In the second example, the end time is a five minutes earlier than the start time which indicates a backward jump in time.
Note:
sps.log contains the following: