Node-API (NAPI) init script fails to finish within timeout of 5 mins in NSX-T
searchcancel
Node-API (NAPI) init script fails to finish within timeout of 5 mins in NSX-T
book
Article ID: 321138
calendar_today
Updated On: 11-12-2018
Products
VMware NSX
Issue/Introduction
Symptoms:
Operations or Command Line Interface using the NAPI server fails.
CCP-MP registration fails.
You see the error:
Unable to retrieve manager configuration.
Environment
VMware NSX-T Data Center VMware NSX-T Data Center 2.x
Cause
This issue occurs due to the N-API init timing out as loading of Docker images are slow. This may occur during the first boot during installation or first boot after upgrade of the Controllers. It can also be identified immediately before it can impact the data traffic. Some CLIs can fail and require a reboot to resolve but there is no impact on the data traffic.
Resolution
This is a known issue affecting VMware NSX-T Data Center 2.3.x.
Currently, there is no resolution.
Workaround: To work around this issue, reboot the affected Controllers.