Quality of Service displays incorrect values after importing VLAN from NSXT in Cloud Director 10.3.3
book
Article ID: 320455
calendar_today
Updated On:
Products
VMware Cloud Director
Issue/Introduction
Symptoms:
Provider Portal > Infrastructure Resources > Segment Profile Templates > Segment Profile > Quality of Service displays incorrect values after importing VLAN from NSXT in Cloud Director 10.3.3.
Quality of Service values show correctly in the NSXT UI.
The REST API returns the correct data, but there is a mismatch displaying in the UI.
Environment
VMware Cloud Director 10.x
Cause
The issue occurs when there are multiple QoS segment profiles.
The API used to return the segment profiles returns multiple values but the UI only uses first one to populate the values on screen..
Resolution
This is a Known Issue affecting VMware Cloud Director 10.3.3. The issue is resolved in VMware Cloud Director 10.4, available at Broadcom Downloads.