VMware vSphere ESXi
The issue may occur when:
The device latency may increase due to:
The numbers reported in the events are in microseconds and refer to the DAVG measurements in the esxtop storage screen.
Refer: Using esxtop to identify storage performance issues for ESXi
Latency is a measure of the round-trip time between the issuance of a SCSI command from the hypervisor, through the transport to the surface of the media, and the return. Therefore, the source of the delay could be anywhere in the fabric, the storage infrastructure, or anywhere along the storage path.
Performance Benchmarks:
From Esxi, var/run/log/vmkernel.log there is an event for "performance has deteriorated"
[YYYY-MM-DDTHH:MM:SS] cpu51:2098041)WARNING: ScsiDeviceIO: 513: Device naa.########## performance has deteriorated. I/O latency increased from average value of 38762 microseconds to 776315 microseconds.[YYYY-MM-DDTHH:MM:SS] cpu47:2098037)WARNING: ScsiDeviceIO: 1443: Device naa.######### performance has deteriorated. I/O latency increased from average value of 12017 microseconds to 254228 microseconds.[YYYY-MM-DDTHH:MM:SS] cpu47:2098038)WARNING: ScsiDeviceIO: 1216: Device naa.######### performance has deteriorated. I/O latency increased from average value of 18057 microseconds to 534229 microseconds.
High device latency:
Overload conditions:
Latency duration:
vmkernel.log to determine the time elapsed between the "performance has deteriorated" log entry and the "performance has improved" log entry.Characterizing Observed Latency: Use the following framework to investigate:
For more information, see .
Note: ESXi does not cause latency spikes; it merely reports them. While the root cause cannot be determined from the ESXi perspective alone, the data above guides an investigation into the external storage infrastructure.