VMware vSphere ESXi 8.0
VMware vSphere ESXi 7.0
This Alarm is triggered when threshold for a LUN is met/exceeded in an environment that utilises thin-provisioned devices or storage pools.
The initial threshold can be set as either soft or hard; however, only a hard threshold will prevent any further data from being allocated.
In the /var/log/vobd.log file of the ESXi host, you see entries similar to:
Space utilization on the thin-provisioned device naa.xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx exceeded the configured threshold.
####-##-##T##:##:##.###Z cpu59:33773)NMP: nmp_ThrottleLogForDevice:3333: Cmd 0x8a (0x43be1e8451c0, 81679675) to dev "naa.xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx" on path "vmhba##:C#:T#:L##" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x38 0x7. Act:NONE
####-##-##T##:##:##.###Z cpu59:33773)WARNING: ScsiDeviceIO: 2420: Space utilization on thin-provisioned device naa.xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx exceeded configured threshold To resolve this issue, contact the storage vendor to modify the capacity thresholds, following their specific recommendations.
In come cases it may be necessary to add additional space to the backing storage pool.