Host configuration: Failed to send the HostConfig message. [TN=TransportNode/<UUID>]. Reason: Mac address for a vnic fp-eth0 is not found on edge node /infra/sites/default/enforcement-points/default/edge-transport-node/<UUID>.
Edge 3.2.0.0.0.19067070/Edge/nub/VMware-NSX-edge-3.2.0.0.0.19067089.nub switch OS task failed on edge TransportNode <UUID>: clientType EDGE , target edge fabric node id <UUID>, return status switch_os execution failed with msg: An unexpected exception occurred: <......snip.....> ERROR: NSX Edge configuration has failed. 1G hugepage support required\n"
This is a known issue impacting NSX-T Data Center 3.2.0 and 3.2.0.1.
This issue is resolved in VMware NSX-T 3.2.1 (build number 19801959).
Workaround:
A configuration change must be made to the Edge VM to allow it use 1GB hugepages.
featMask.vm.cpuid.PDPE1GB = Val:1
Note:
In the case of an upgrade failure, retry the upgrade once the configuration change is complete.
Alternatively, the Edge VM can instead be moved to an ESXi host with a newer generation CPU which by default allows 1GB hugepages.