Symptoms:
Stretch cluster failure is reported in UI and the below failure is seen from domainmanager log:
2023-05-23T04:08:41.035+0000 ERROR [vcf_dm,1a6061cf05d4e7b6,9b26] [c.v.v.c.n.s.i.Nsxt30xTransportNodeCreationServiceImpl,dm-exec-17] Error creating TransportNode for Host: <servername>.
com.vmware.vapi.std.errors.InvalidRequest: InvalidRequest (com.vmware.vapi.std.errors.invalid_request) => {
messages = [],
data = struct => {error_message=The uplink name uplink-3 is not found in the [uplink-2, uplink-1] list of UplinkHostSwitchProfile BaseHostSwitchProfile/########-####-####-####-########8e26., httpStatus=BAD_REQUEST, error_code=8217, module_name=NsxSwitching service},
errorType = INVALID_REQUEST
}
This issue will occur when there are more than 2 NICs mapped to overlay traffic.
To workaround the issue, please follow the steps mentioned under For VCF 5.0 in VMware Cloud Foundation : NSX-T uplink profile configuration to reduce NICs