Design Decision: On all vSAN datastores, ensure that at least 30% of free space is always available.

Resolution

Design Justification: When vSAN reaches 80% usage, a rebalance task is started which can be resource-intensive.

Design Implication: Increases the amount of available storage needed.

This design decision is supported in the following Domains. 
•    Management Domain
•    VI Workload Domain

This design decision is supported on VCF version 4.1 and higher. 