VMware Cloud Foundation - Design Decision - Set host isolation to Power Off and Restart VMs in vSphere HA.
search cancel

VMware Cloud Foundation - Design Decision - Set host isolation to Power Off and Restart VMs in vSphere HA.

book

Article ID: 318097

calendar_today

Updated On:

Products

VMware VMware Cloud Foundation

Issue/Introduction

Design Decision: Set host isolation to Power Off and Restart VMs in vSphere HA.

Resolution

Design Justification: vSAN requires that the host isolation response be set to Power Off and to restart VMs on available ESXi hosts.

Design Implication: If a false-positive event occurs, VMs are powered off and an ESXi host is declared isolated incorrectly.

This design decision is supported in the following Domains. 
•    Management Domain
•    VI Workload Domain

This design decision is supported on VCF version 4.1 and higher. 

Note: To search for additional information on this design decision please search on the design decision text in https://docs.vmware.com/. For example https://docs.vmware.com/en/search/#/%22Enable%20Network%20I%2FO%20Control%20on%20all%20distributed%20switches.%22

Additional Information

Please reference the VMware Cloud Foundation version you are running and if this design decision is applicable to you. 