VMware Cloud Foundation - Design Decision - Configure vSAN in All-Flash mode in the shared edge and workload cluster.
book
Article ID: 318071
calendar_today
Updated On:
Products
VMwareVMware Cloud Foundation
Issue/Introduction
Design Decision: Configure vSAN in All-Flash mode in the shared edge and workload cluster.
Resolution
Design Justification: - Provides support for vSAN deduplication and compression. - Meets the performance needs of the shared edge and workload cluster.
Using high speed magnetic disks in a hybrid vSAN configuration can provide satisfactory performance and is supported.
Design Implication: More disks might be required per host because flash disks are not as dense as magnetic disks.
This design decision is supported in the following Domains. • Management Domain • VI Workload Domain
This design decision is supported on VCF version 4.1 and higher.
Note: To search for additional information on this design decision please search on the design decision text in https://docs.vmware.com/. For example https://docs.vmware.com/en/search/#/%22Enable%20Network%20I%2FO%20Control%20on%20all%20distributed%20switches.%22
Additional Information
Please reference the VMware Cloud Foundation version you are running and if this design decision is applicable to you.