VMware Cloud Foundation - Design Decision - Configure vSAN in All-Flash mode in the shared edge and workload cluster.
search cancel

VMware Cloud Foundation - Design Decision - Configure vSAN in All-Flash mode in the shared edge and workload cluster.

book

Article ID: 318071

calendar_today

Updated On:

Products

VMware VMware Cloud Foundation

Issue/Introduction

Design Decision: Configure vSAN in All-Flash mode in the shared edge and workload cluster.

Resolution

Design Justification:
- Provides support for vSAN deduplication and compression.
-  Meets the performance needs of the shared edge and workload cluster.

Using high speed magnetic disks in a hybrid vSAN configuration can provide satisfactory performance and is supported.

Design Implication: More disks might be required per host because flash disks are not as dense as magnetic disks.

This design decision is supported in the following Domains. 
•    Management Domain
•    VI Workload Domain

This design decision is supported on VCF version 4.1 and higher. 

Note: To search for additional information on this design decision please search on the design decision text in https://docs.vmware.com/. For example https://docs.vmware.com/en/search/#/%22Enable%20Network%20I%2FO%20Control%20on%20all%20distributed%20switches.%22

Additional Information

Please reference the VMware Cloud Foundation version you are running and if this design decision is applicable to you. 

VMware Validated Design (VVD) Bill of Materials