ESXi 7.0 U3L upgrade from Dell OEM ISO loads driver 4.1.9 driver but disconnects the host post reboot
search cancel

ESXi 7.0 U3L upgrade from Dell OEM ISO loads driver 4.1.9 driver but disconnects the host post reboot

book

Article ID: 318039

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • Upgrade of ntg3 driver to version 4.1.9.0-4vmw might cause link issues in fiber physical layer and connectivity on some NICS will be down such as Broadcom 1Gb.
  • Broadcom NICs with fiber physical connectivity might lose network. 
vmkernel.log:
YYYY-MM-DDTHH:MM:SS.689Z cpu44:2097903)Device: 507: ntg3:driver->ops.scanDevice:0 ms
YYYY-MM-DDTHH:MM:SS.007Z cpu2:2097340)ntg3:0000:18:00.0:Ntg3UplinkAssociate:1131:Associated with vmnic0
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Uplink: 12244: Device vmnic0 not yet opened
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Device: 395: uplink_drv:driver->ops.attachDevice :0 ms
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Device: 400: Found driver uplink_drv for device 0x461943084701d68c
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Uplink: 14658: Opening device vmnic0
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Uplink: 12269: The default queue id for vmnic0 is 0x44000.
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)VMKAPIMOD: 110: failed to query port alias for Not found:
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Uplink: 12282: enabled port 0x82000002 with mac XX:XX:XX:XX:XX:XX
YYYY-MM-DDTHH:MM:SS.007Z cpu46:2097954)Uplink: 2750: vmnic0, fast switch on uplink(0x82000002) connected to PPS is not supported
YYYY-MM-DDTHH:MM:SS.007Z cpu2:2097340)ntg3:vmnic0:Ntg3UplinkStateSet:614:Setting uplink state to 0x1d
YYYY-MM-DDTHH:MM:SS.007Z cpu2:2097340)ntg3:vmnic0:Ntg3UplinkStartIO:672:Ntg3UplinkStartIO 

Environment

VMware vSphere ESXi 7.0.3

Cause

Link down state condition for Broadcom 1 GB cards is observed when patching to VMware image "VMware-VMvisor-Installer-7.0U3l-21424296" with driver VMW_bootbank_ntg3_4.1.9.0-4vmw.

Resolution

  • This issue is fixed in ESXi 7.0 Update 3m release.
  • ESXi 7.0 Update 3m provides ntg3 driver version 4.1.9.0-5vmw. The fix also adds a module parameter, fifoElastic, which you can enable in case of jumbo frame drops in certain Dell switches. To enable the parameter, use the following command:

    esxcli system module parameters set -p 'fifoElastic=1' -m ntg3

Additional Information

Impact/Risks:
  • Upon reboot after patch, the host is in a disconnected state if Broadcom 1 GB cards are used for the management network