vSAN host enters PSOD state sporadically when Storage Accelerator and virtual NVMe controllers are used
book
Article ID: 317853
calendar_today
Updated On:
Products
VMware vSAN
Show More
Show Less
Issue/Introduction
Symptoms:
You are running ESXi 7.0 U3c or newer.
You are seeing different hosts sporadically entering PSOD within the same vSAN cluster.
You have "Storage Accelerator" (CBRC) of Horizon enabled in the cluster.
One or more virtual machines using the virtual NVMe Controller are located on the vSAN datastore.
The virtual machine using the virtual NVMe Controller has at least one snapshot.
The PSOD stacktrace shown is very similar to:
[email protected]
#0.0.0.1+0x12dc stack: 0x45d9800d1080
[email protected]
#0.0.0.1+0x990 stack: 0x431e3e6c4070
[email protected]
#0.0.0.1+0x16 stack: 0x0
[email protected]
#0.0.0.1+0x9c4 stack: 0xc000000
[email protected]
#0.0.0.1+0x19 stack: 0x453967a9bf10
[email protected]
#0.0.0.1+0x4a stack: 0x45d9c61f7448
[email protected]
#0.0.0.1+0x637 stack: 0x1e6580a69fe0f2
vmkWorldFunc@vmkernel#nover+0x49 stack: 0x42000751dd6c
CpuSched_StartWorld@vmkernel#nover+0x86 stack: 0x0
Debug_IsInitialized@vmkernel#nover+0xc stack: 0x0
Environment
VMware vSAN 7.0.x
Cause
When above symptoms match, during NVMe SCSI emulation a unexpected state caused the host not to be able to correctly process the I/O.
Resolution
This has been addressed in ESXi 7.0 U3i.
Workaround:
Use a different virtual storage controller on your virtual machines other than virtual NVMe controller.