ESXi Hosts fails to perform a network failover when the fabric Interconnect fails in a Cisco UCS
book
Article ID: 317602
calendar_today
Updated On:
Products
VMware vSphere ESXi
Issue/Introduction
Symptoms:
- Network failover does not work properly on ESXi host when Cisco UCS Fabric Interconnect (FI) rebooted.
- Network failover works fine on hosts running ESXi 6.x and 7.x
- In the /var/log/vobd.log file, you see entries similar to:
<YYYY-MM-DD>T<time>: [netCorrelator] 88463498397us: [vob.net.pg.uplink.transition.down] Uplink: vmnic0 is down. Affected portgroup: Management Network. 1 upl
</time>inks up. Failed criteria: 128
<YYYY-MM-DD>T<time>: [netCorrelator] 88463498456us: [vob.net.vmnic.linkstate.down] vmnic vmnic0 linkstate down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88463498493us: [vob.net.pg.uplink.transition.down] Uplink: vmnic2 is down. Affected portgroup: NFS. 1 uplinks up. Failed
</time> criteria: 128
<YYYY-MM-DD>T<time>: [netCorrelator] 88463498557us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88463498849us: [vob.net.vmnic.linkstate.down] vmnic vmnic4 linkstate down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88463498883us: [vob.net.vmnic.linkstate.down] vmnic vmnic6 linkstate down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88464190143us: [esx.problem.net.vmnic.linkstate.down] Physical NIC vmnic4 linkstate is down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88464190246us: [esx.problem.net.vmnic.linkstate.down] Physical NIC vmnic6 linkstate is down
</time><YYYY-MM-DD>T<time>: [netCorrelator] 88465188551us: [esx.problem.net.redundancy.lost] Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic
</time>0 is down. Affected port groups: "Management Network"
<YYYY-MM-DD>T<time>: [netCorrelator] 88465188725us: [esx.problem.net.redundancy.lost] Lost uplink redundancy on virtual switch "vSwitch1-NFS". Physical NIC vmnic2 is down. Affected port groups: "NFS"</time>
Note: This log excerpt is an example. Date, time, and environmental variables may vary depending on your environment.
Environment
VMware vSphere ESXi 7.x
VMware vSphere ESXi 6.x
Resolution
This is a known issue affecting VMware ESXi 6.5 running on nenic 1.0.1.x NIC driver for Cisco.
Filter the appropriate ESXi version.
Go to Drivers & Tools tab.
Search with "nenic".
Feedback
thumb_up
Yes
thumb_down
No